Tunable filter design for IR hyperspectral imaging - Université Polytechnique des Hauts-de-France Access content directly
Poster Communications Year : 2019

Tunable filter design for IR hyperspectral imaging

Abstract

The use of wide-angle Acousto-Optic Tunable Filter (AOTF) for hyperspectral imaging is considered: the diffraction efficiency is calculated around a usual diffraction plane for two degrees of freedom (azimuthal and transverse angle). The efficiency evolution is also examined over a wide wavelength band. The diffraction efficiency is determined as a function of the incident angles and the results are commented. The spectral bandwidth is also studied.
No file

Dates and versions

hal-03549446 , version 1 (31-01-2022)

Identifiers

Cite

Justine Champagne, Samuel Dupont, Joseph Gazalet, Jean-Claude Kastelik. Tunable filter design for IR hyperspectral imaging. 44th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz), Sep 2019, Paris, France. IEEE, pp.1-2, ⟨10.1109/IRMMW-THz.2019.8874428⟩. ⟨hal-03549446⟩
12 View